Do You Need Technical Support & Application Assistance?

Fred, our company mascot, is at your service. Don't let his appearance fool you. Fred is an experienced and knowledgeable bin level measurement application specialist.

Click Here to submit your question to Fred & others from our Technical Support Team...you will receive a response by e-mail or telephone within one business day.

-OR- Call us at 800-601-6319 / 630-365-9403 (Outside US) to talk with one of our technical specialists.

Monitor Technologies, we have a solution for you!

 

 

 
TrueCap Level SensorTrueCap Light  
TrueCap® MK-2
Advanced RF Capacitance Level Probe
The TrueCap® Model MK-2 RF Capacitance point level probe is designed to provide a superior and stable sensitivity threshold making it suitable for a variety of powder / bulk solids and some liquid or slurry applications.

Advanced features of the Model MK-2 include:
> Automatic immunity to material build-up on the probe by its driven shield design
> Push-button calibration
> Enhanced temperature compensation
> Maximized reliability via smart sensing algorithms like “self-validating” fail-safe protection
> Visible status LED on ordinary location units
> Versatility through a variety of configuration options including: hazardous location version, split architecture design, quick-connect process connection, stub probe, cable extensions, solid extensions, Nylon® probes, Ryton® - equiv. probes, etc.

A practical application for the TrueCap would be to use this level sensor where a residual material build-up on a different sensor would cause a false material level indication.

Principle of Operation for the TrueCap RF Capacitance Level Probe:
The vessel wall and the active probe element establish an impedance reference between each other when exposed to air which has a dielectric constant of 1. When materials with a dielectric constant greater than 1 are in close proximity to the probe, the impedance of the sensing field between the sensor and the vessel wall will change. Once the amount of change exceeds a threshold that was electronically determined during the calibration process, an output relay will either be energized or de-energized depending upon the position of the fail-safe selector on the probe’s electronic circuit board. A change of as little as .5 pico-farad is all that is necessary for the probe to sense the presence of material.

Click here for more information on the TrueCap MK-2 Level Sensor or contact Monitor Technologies LLC at
Tel.: 800-766-6486 in the USA and
Tel.: 630-365-9403 worldwide.
 
>>Download TrueCap Product Bulletin #413
>>Click here to learn more about other Point Level Switches from Monitor Technologies

Join Monitor's E-Mailing List!
Enter your Email Address Here:


 
 


Site Map Solutions Contact Us
Continuous Level Measurement Showcase Rep Locator
Point Bin Level Indicators About Monitor Industry Links
Other Instruments Privacy Statement Mobile View

Home

 

Copyright © 2014 MONITOR TECHNOLOGIES, LLC. ALL RIGHTS RESERVED

800.601.6319 or 630.365.9403

 
Translate This Web Page: